产品分类
联系我们
北京恒奥德科技有限公司 010-51666869 传 真:010-69807135 13120411557 18701256112 联系人:李红慧 1575574360 1321298635 1445496132 号院16号楼317 (北京市地质工程勘察院院内)
|
新闻动态
公司最近出口一批多参数水产养殖检测仪 水产养殖检测仪 现货 特价
Multifunctional aquaculture tester
DZ-A
An instruction manual
Beijing Heng Aode Technology Co. Ltd.
Thank you for purchasing multifunctional aquaculture tester product, please read this manual carefully before using this product, to make the proper use of.
开箱检查
The open package inspection
1.仪器 1台
1 instruments 1
2.玻璃样槽 2个
2 glass slot 2
3.样槽盖 1个(黑色)
3 slot cover 1 (black)
4.电源线 1根
4 power line 1
5.合格证 1张
5 Certificate 1
6.说明书 1本
The 6 Manual 1
7.溶解氧反应瓶 1只
7 oxygen reaction bottle 1
8.锂电池 1只
8 lithium battery 1
一、 产品概述
A, product introduction
DZ-A多功能水产养殖测试仪用于测量水中溶解氧、氨氮、亚硝酸盐的检测。本仪器可用于水产养殖等部门,是常用的实验室仪器。
DZ-A multifunctional aquaculture test instrument is used for measuring the water dissolved oxygen, ammonia nitrogen, nitrite. The instrument can be used for aquaculture and other departments, is a common laboratory instrument.
二、 技术参数
Two, the technical parameters
氨氮 溶解氧 亚硝酸盐
Ammonia dissolved oxygen, nitrite
测量范围 0-10 mg/L 0-12 mg/L 0-0.3mg/L
Measuring range of 0-10 0-12 mg/L 0-0.3mg/L mg/L
分辨率 0.01mg/L
Resolution 0.01mg/L
重复性 ≤2%
Repetitive ≤ 2%
示值误差 ±5%FS
The indication error of ± 5%FS
电源 AC 220V 50Hz
The power of AC 220V 50Hz
三、 特点:
Three, characteristics:
1.微电脑,触摸式键盘使用方便。
1 microcomputer, easy to use touch type keyboard.
2 auto zero and 1 ~ 5 point automatic calibration.
3.标准光学玻璃样槽互换性更强。
3 standard optical glass groove exchangeability of.
4.本仪器采用独特的半导体发光器(专利申请号99226785.2),其光源寿命较白
4 the instrument adopts the unique semiconductor light emitting device (patent application No. 99226785.2), the light source life than the white
炽灯(约350小时)高出几个数量级,约几万小时。
Incandescent lamps (about 350 hours) several orders of magnitude higher, about tens of thousands of hours.
5.交直流两用,高性能锂电池,充电2小时可连续使用4小时,即充即用。
5 AC-DC dual-use, high performance lithium battery, charging 2 hours to 4 hours of continuous use, charging and using.
6 high resolution. The resolution can reach 0.01 meters.
四、 操作指南
Four, operation guide
1. 面板按键说明
The 1 panel shows
2. 选择测试项
2 select test items
打开电源开关,按下选择键,屏幕显示闪烁的数字(量程),再次按下选择键,屏幕显示下一个量程,当选定某项量程时,请按下读数键,屏幕不再显示闪烁的数字(量程),选择量程完成。关机后会自动记忆当前选择的量程。
Turn on the power switch, press the select key, the screen display flashing digits (range), press the select key again, the screen showing a range, when you select a range, press the reading keys, the screen no longer display flashing digital (range), select the range to complete. After the shutdown will range automatic memory of the current selection.
各数字参数的定义:
Definition of the numerical parameters:
10.00 氨氮 0-10mg/L量程
10 - 0-10mg/L range
12.00 溶解氧0-12mg/L量程
12 dissolved oxygen 0-12mg/L range
00.30 亚硝酸盐0-0.3mg/L量程
0.30 nitrite 0-0.3mg/L range
3. 氨氮检测方法
3 ammonia detection method
① 打开电源开关,将零度水(纯净水)倒入玻璃样槽并放入样槽座,盖上样槽盖,按下清零键,屏幕显示闪烁的00.00,表示正在进行清零,当屏幕不再显示闪烁的数字时,清零结束。
The power switch is opened, the zero water (pure water) poured into a glass tank and into the sample groove seat, cover the sample tank cover, press the reset button, the screen display flashing 0, said it was clear, when the screen no longer display flashing digits, zero end.
② 将被测水样倒入玻璃样槽,放入氨氮试剂(1)10滴摇匀,再加氨氮试剂(2)10滴摇匀静置5分钟后放入样槽座,盖上样槽盖,按下读数键,等待几秒钟显示读数(氨氮值)即可。每次读数都需按下读数键。
The measured water sample into a glass tank, add ammonia reagent (1) 10 drops shaken, plus ammonia reagent (2) 10 drops shaken after standing for 5
minutes into the sample groove seat, cover the sample tank cover, press the reading keys, wait a few seconds display reading (ammonia). Each reading press keys are required reading.
4. 溶解氧检测方法
4 measurement methods of dissolved oxygen
① 打开电源开关,将零度水(纯净水)倒入玻璃样槽并放入样槽座,盖上样槽盖,按下清零键,屏幕显示闪烁的00.00,表示正在进行清零,当屏幕不再显示闪烁的数字时,清零结束。
The power switch is opened, the zero water (pure water) poured into a glass tank and into the sample groove seat, cover the sample tank cover, press the reset button, the screen display flashing 0, said it was clear, when the screen no longer display flashing digits, zero end.
② 将被测水样沿着反应瓶管壁缓慢倒入反应瓶中至满,放入试剂(1)和(2)各10滴,拧上盖子上下颠倒转动几次(瓶内不允许有气泡),使瓶内溶液充分混合后静置,待瓶内沉淀物沉至三分之一左右,再上下颠倒转动几次,使瓶内溶液充分混合,再次静置使沉淀物沉至三分之一左右,加入试剂(3)10滴,拧上盖子上下颠倒转动几次,使瓶内沉淀物完全溶解(若不完全溶
The measured water samples along the reaction tube wall slowly poured into the reaction bottle to the full, into the reagent (1) and (2) 10 drops each screw on the lid upside down, turning several times (bottles are not allowed inside the bubble), bottle solution mix static, the bottle sediment sink to 1/3 or so, and then upside down turning several times, so that the bottle of solution mixing, once again standing to sediment sink to around 1/3, add 10 drops of reagent (3), screw the lid upside down turning several times, so that the bottle deposit completely dissolved (if not completely soluble The solution can be coupled with the reagent (3) 1-2 drops), poured into the glass like groove, groove seat cover into the sample, sample slot cover, press the reading keys, wait a few seconds display reading (dissolved oxygen value). Each reading to reading keys.
5.亚硝酸盐检测方法
5 detection of nitrite method
① 打开电源开关,将零度水(纯净水)倒入玻璃样槽并放入样槽座,盖上样槽盖,按下清零键,屏幕显示闪烁的00.00,表示正在进行清零,当屏幕不再显示闪烁的数字时,清零结束。
The power switch is opened, the zero water (pure water) poured into a glass tank and into the sample groove seat, cover the sample tank cover, press the reset button, the screen display flashing 0, said it was clear, when the screen no longer display flashing digits, zero end.
② 将被测水样倒入玻璃样槽,放入1勺试剂摇匀静置5分钟后放入样槽座,盖上样槽盖,按下读数键,等待几秒钟显示读数(亚硝酸盐值)即可。每次读数都需按下读数键。
The measured water sample into a glass tank, put in 1 teaspoons of reagent shake after standing for 5 minutes into the sample groove seat, cover the sample tank cover, press the reading keys, wait a few seconds display reading (nitrite values). Each reading press keys are required reading.
五、 校准
Five, calibration
1.标准液
1 standard solution
仪器出厂已标定,可直接使用,若用户需要重新标定,请自行配备标准液。
Instrument factory has been calibrated, and can be used directly, if the user needs to re calibration, please with standard solution.
六、 注意事项
In six, the matters needing attention
1.水样倒入玻璃样槽后,请用强吸水的软布或纸擦干玻璃样槽外的水渍(手指勿直接接触玻璃样槽表面,以免在玻璃样槽表面留下指纹,影响测试结果)。
1 water into the glass tank, please use the strong water absorbing soft cloth or paper wipe the glass tank of water (finger not to directly touch the glass surface of the groove, so as not to leave any fingerprints, in the glass groove surface influence the test results).
2.切断电源后方可清洁仪器。
2 cut off the power supply before cleaning instrument.
3.清除显示器上污渍请用软布或棉纸。
3 remove display. Use a soft cloth or tissue paper.
4.显示器表面易被划伤,禁止用硬物擦拭或触及。
The 4 display surface is easy to be scratched, prohibited wipe or touched with a hard object.
5.样槽必须保持干净,使用后用蒸馏水冲洗,洗后倒置避免粉尘进入。
5 slot must be kept clean after use, rinsed with distilled water, after washing to avoid dust entering the inversion.
6.水样加入样槽,不要让气泡进入,脱泡方法为静置一段时间。
6 water adding sample bath, don't let the entry of air bubbles, defoaming method for a period of time.
7.玻璃样槽放入样槽座时,应把玻璃样槽上有标线的一面面向操作者。
7 glass tank into the sample groove seat, should have the marking glass groove on the side facing the operator.
北京恒奥德科技有限公司 010-51666869 传 真:010-69807135 13120411557 18701256112 联系人:李红慧 1575574360 1321298635 1445496132 号院16号楼317 (北京市地质工程勘察院院内)
|